BRACKETOLOGY | FEDRAMP
MA-4: NONLOCAL MAINTENANCE
-
FedRAMP Baseline Membership MA-4:
- LOW
- MODERATE
- HIGH
FedRAMP Bracketology
Use the FedRAMP Control Membership information above to determine if a control or control enhancement is required for each Impact Baseline — LOW, MODERATE, or HIGH
Click on the panel below each control or control enhancement to review the FedRAMP Impact Baseline-specific control configuration requirements for each of the [BRACKETS] in each control and/or control enhancement.
Review and use Additional Requirements and Guidance to build FedRAMP-compliant controls for your risk-based cybersecurity program.
To change the baseline view in the panel, click on LOW, MODERATE, or HIGH when the panel is open
Panels only appear where there are [BRACKETS] in the control or enhancement or where there is FedRAMP-specific requirements or guidance available.
The organization:
- a. Approves and monitors nonlocal maintenance and diagnostic activities;
- b. Allows the use of nonlocal maintenance and diagnostic tools only as consistent with organizational policy and documented in the security plan for the information system;
- c. Employs strong authenticators in the establishment of nonlocal maintenance and diagnostic sessions;
- d. Maintains records for nonlocal maintenance and diagnostic activities; and
- e. Terminates session and network connections when nonlocal maintenance is completed.
SUPPLEMENTAL GUIDANCE
Nonlocal maintenance and diagnostic activities are those activities conducted by individuals communicating through a network, either an external network (e.g., the Internet) or an internal network. Local maintenance and diagnostic activities are those activities carried out by individuals physically present at the information system or information system component and not communicating across a network connection. Authentication techniques used in the establishment of nonlocal maintenance and diagnostic sessions reflect the network access requirements in IA-2. Typically, strong authentication requires authenticators that are resistant to replay attacks and employ multifactor authentication. Strong authenticators include, for example, PKI where certificates are stored on a token protected by a password, passphrase, or biometric. Enforcing requirements in MA-4 is accomplished in part by other controls.
RELATED CONTROLS: MA-4
CONTROL ENHANCEMENTS
MA-4 (1) NONLOCAL MAINTENANCE | AUDITING AND REVIEW
The organization:
- (a) Audits nonlocal maintenance and diagnostic sessions [Assignment: organization-defined audit events]; and
- (b) Reviews the records of the maintenance and diagnostic sessions.
Supplemental Guidance: NONE
RELATED CONTROLS: MA-4 (1)
MA-4 (2) NONLOCAL MAINTENANCE | DOCUMENT NONLOCAL MAINTENANCE
-
FedRAMP Baseline Membership MA-4 (2):
- MODERATE
- HIGH
The organization documents in the security plan for the information system, the policies and procedures for the establishment and use of nonlocal maintenance and diagnostic connections.
Supplemental Guidance: NONE
MA-4 (3) NONLOCAL MAINTENANCE
-
FedRAMP Baseline Membership MA-4 (3):
- HIGH
The organization:
- (a) Requires that nonlocal maintenance and diagnostic services be performed from an information system that implements a security capability comparable to the capability implemented on the system being serviced; or
- (b) Removes the component to be serviced from the information system prior to nonlocal maintenance or diagnostic services, sanitizes the component (with regard to organizational information) before removal from organizational facilities, and after the service is performed, inspects and sanitizes the component (with regard to potentially malicious software) before reconnecting the component to the information system.
Supplemental Guidance: NONE
RELATED CONTROLS: MA-4 (3)
Supplemental Guidance:
Comparable security capability on information systems, diagnostic tools, and equipment providing maintenance services implies that the implemented security controls on those systems, tools, and equipment are at least as comprehensive as the controls on the information system being serviced.
MA-4 (4) NONLOCAL MAINTENANCE | AUTHENTICATION / SEPARATION OF MAINTENANCE SESSIONS
The organization protects nonlocal maintenance sessions by:
- (a) Employing [Assignment: organization-defined authenticators that are replay resistant]; and
- (b) Separating the maintenance sessions from other network sessions with the information system by either:
- Physically separated communications paths; or
- Logically separated communications paths based upon encryption.
Supplemental Guidance: NONE
RELATED CONTROLS: MA-4 (4)
MA-4 (5) NONLOCAL MAINTENANCE | APPROVALS AND NOTIFICATIONS
The organization:
- (a) Requires the approval of each nonlocal maintenance session by [Assignment: organization-defined personnel or roles]; and
- (b) Notifies [Assignment: organization-defined personnel or roles] of the date and time of planned nonlocal maintenance.
Supplemental Guidance:
Notification may be performed by maintenance personnel. Approval of nonlocal maintenance sessions is accomplished by organizational personnel with sufficient information security and information system knowledge to determine the appropriateness of the proposed maintenance.
MA-4 (6) NONLOCAL MAINTENANCE | CRYPTOGRAPHIC PROTECTION
-
FedRAMP Baseline Membership MA-4 (6):
- HIGH
The information system implements cryptographic mechanisms to protect the integrity and confidentiality of nonlocal maintenance and diagnostic communications.
Supplemental Guidance: NONE
RELATED CONTROLS: MA-4 (6)
MA-4 (7) NONLOCAL MAINTENANCE | REMOTE DISCONNECT VERIFICATION
The information system implements remote disconnect verification at the termination of nonlocal maintenance and diagnostic sessions.
Supplemental Guidance:
Remote disconnect verification ensures that remote connections from nonlocal maintenance sessions have been terminated and are no longer available for use.
RELATED CONTROLS: MA-4 (7)
REFERENCES:
- CNSS Policy 15
- FIPS Publication 140-2
- FIPS Publication 197
- FIPS Publication 201
- NIST Special Publication 800-63
- NIST Special Publication 800-88